2015年8月18日星期二

Fluke Multimode OTDR for troubleshooting and extended certification – 2

Fluke Multimode OTDR
Fluke Multimode OTDR
Fluke Multimode OTDR Introduction:
Multimode moduleSinglemode moduleQuad module
Wavelengths850 nm +/- 10 nm
1300 nm +35/-15 nm
1310 nm +/- 25 nm
1550 nm +/- 30 nm
850 nm +/- 10 nm
1300 nm +35/-15 nm
1310 nm +/- 25 nm
1550 nm +/- 30 nm
Compatible fiber types50/125 μm
62.5/125 μm
Singlemode50/125 μm
62.5/125 μm
Singlemode
Event dead zone 1850 nm: 0.5 m (typical)
1300 nm: 0.7 m (typical)
1310 nm: 0.6 m (typical)
1550 nm: 0.6 m (typical)
850 nm: 0.5 m (typical)
1300 nm: 0.7 m (typical)
1310 nm: 0.6 m (typical)
1550 nm: 0.6 m (typical)
Attenuation dead zone 2850 nm: 2.2 m (typical)
1300 nm: 4.5 m (typical)
1310 nm: 3.6 m (typical)
1550 nm: 3.7 m (typical)
850 nm: 2.2 m (typical)
1300 nm: 4.5 m (typical)
1310 nm: 3.6 m (typical)
1550 nm: 3.7 m (typical)
Dynamic range 3, 5, 6850 nm: 28 dB (typical)1300 nm: 30 dB (typical)1310 nm: 32 dB (typical)1550 nm: 30 dB (typical)850 nm: 28 dB (typical)
1300 nm: 30 dB (typical)
1310 nm: 32 dB (typical)
1550 nm: 30 dB (typical)
Max distance range setting40 km130 kmMM: 40 km
SM: 130 km
Distance measurement range 4, 5, 7, 8, 9, 10850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km
850 nm: 9 km
1300 nm: 35 km
1310 nm: 80 km
1550 nm: 130 km
Reflectance range 4, 5850 nm: -14 dB to -57 dB (typical)1300 nm: -14 dB to -62 dB (typical)1310 nm: -14 dB to -65 dB (typical)
1550 nm: -14 dB to -65 dB (typical)
850 nm: -14 dB to -57 dB (typical)
1300 nm: -14 dB to -62 dB (typical)
1310 nm: -14 dB to -65 dB (typical)
1550 nm: -14 dB to -65 dB (typical)
Sample resolution3 cm to 400 cm3 cm to 400 cm3 cm to 400 cm
Pulse widths (nominal)850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
3, 10, 30, 100, 300, 1000,
3000, 10000, 20000 ns
850 nm: 3, 5, 20, 40, 200 ns
1300 nm: 3, 5, 20, 40, 200, 1000 ns
1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000,
10000, 20000 ns
Test time (per wavelength)Auto setting: 5 sec (typical)Auto setting: 10 sec (typical)Auto setting:MM – 5 sec (typical) SM – 10 sec (typical)
Quick test setting: 2 sec (typical)Quick test setting: 5 sec (typical)Quick test setting:
MM – 2 sec (typical) SM – 5 sec (typical)
Best resolution setting: 2 to 180 secBest resolution setting: 5 to 180 secBest resolution setting:
MM – 2 to 180 sec SM – 5 to 180 sec
FaultMap setting:
2 sec (typical), 180 sec (max)
FaultMap setting:
10 sec (typical), 180 sec (max)
FaultMap setting:
MM – 2 sec (typical) MM – 180 sec (max)
SM – 10 sec (typical) SM – 180 sec (max)
DataCenter OTDR setting:
1 sec (typical at 850 nm), 7 sec (max)
DataCenter OTDR setting:
20 sec (typical), 40 sec (max)
DataCenter OTDR setting:
MM – 1 sec (typical at 850 nm) MM – 7 sec (max)
SM – 20 sec (typical) SM – 40 sec (max)
Manual setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 secManual setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 secManual setting:
MM – 3, 5, 10, 20, 40, 60, 90, 120, 180 sec
SM – 3, 5, 10, 20, 40, 60, 90, 120, 180 sec

FiberInspector probe specification
Magnification~ 200X with OptiFiber Pro Display
Light sourceBlue LED
Power sourceTFS mainframe
Field of View (FOV)Horizontal: 425 μmVertical: 320 μm
Minimum detectable particle size0.5 μm
DimensionsApproximately 6.75 in x 1.5 in (1175 mm x 35 mm) without adapter tip
Weight200 g
Temperature rangeOperating: 32°F to 122°F (0 °C to +50 °C)
Storage: -4°F to +158°F (20°C to +70°C)
CertificationsCE (when used with the mainframe)
VFL specifications
On/Off controlMechanical switch and a button on the touch screen
Output power316 μw (-5 dBm) ≤ peak power ≤ 1.0 mw (0 dBm)
Operating wavelength650 nm nominal
Spectral width (RMS)±3 nm
Output modesContinuous wave Pulsed mode (2 Hz to 3 Hz blink frequency)
Connector adapter2.5 mm universal
Laser safety(classification)Class II CDRH Complies to EN 60825-2
General specifications
WeightMainframe with module and battery: 3 lbs, 5 oz (1.28 kg)
DimensionsMainframe with module and battery: 2.625 in x 5.25 in x11.0 in ( 6.67 cm x 13.33 cm x 27.94 cm)
BatteryLithium ion battery pack, 7.2 volts
Battery lifeFour hours to charge from 10% capacity to 90% capacity with tester off
Environmental specifications
Operating temperature*-18ºC to 45ºC
Non-operating temperature-30ºC to 60ºC
Operating altitude4,000 m (13,123 ft)
3,200 m (10,500 ft) with AC adapter
Storage altitude12,000 m
EMCEN 61326-1